Mach II
|
Mach II | Newco
|
| |
|
Quote Only
|
Qty:
|
|



|
| |
New! Introducing our portable DIGITAL Ultrasonic Flaw Detector. The compact, reliable and versatile design is ideal for materials in aerospace, nuclear and automotive applications.
FEATURES:
- High resolution/high luminescent screen allows excellent visibility even in direct sunlight.
- Fast and direct access menu makes operation simple.
- User friendly software
- Large capacity memory allows you to save as many A-Scan, B-Scans and C-Scans as you wish!.
- Capable of working with conventional ultrasonic transducers and EMAT generators for non-contact ultrasonic and low frequency transducers for through-transmitting testing.
Mach II Technical Specifications.pdf
SPECIFICATIONS:
PULSER :
- Type: Square wave
- Pulse Amplitude Selectable from 75 to 275 Volts in 5 V steps
- Pulse Width 15 to 5000 ns
- Pulser Excitation Spike (1 pulse) or Burst (1 to 10 pulses)
- Modes SINGLE (Pulse Echo), DUAL (Dual or Through Transmit), EMAT
RECEIVER:
- Bandwidth 0.5 to 30 MHz (at -3 dB)
- Frequency Filters Broadband, Narrowband, or Custom Selectable Low and High Pass Filters 1.0 MHz, 2.0 MHz, 2.25 MHz, 4.0 MHz, 5.0 MHz, 10.0 MHz
- Damping Selection values: 42, 51, 180 or 1000 Ohms
- Gain Control Range 0 to 111.0 dB
- Gain Control Steps Selectable 0.1, 0.5, 1.0 and 6.0 dB
- Display RF, Halfwave+, Halfwave-, Fullwave
TIME BASE:
- Pulse Repetition Rate 10 Hz to 20 kHz
- Test Range 3.8 mm to 14185 mm in steel (for L-waves, at PRF 200 Hz), max. 280 m in steel at PRF 10 Hz
- Display Delay Range -25 mm to 12250 mm (-8.50 μs to 4124 μs)
- Material Velocity 1 to 19999 m/s
- Angle Beam Control Fixed settings of 0°, 30°, 45°, 60°, 70°, 80°,
or variable from 0 to 90° in 0.1° increments
GATES:
- Four independent flaw gates controllable over entire sweep range: Floating gate, Interface gate, Measuring gate – relative, absolute, amplitude, time and back-wall echo attenuator
- Threshold Variable 2.1 to 97.7 % of full screen
- Trigger Logic Positive or Negative
- Gate Synchronization Initial Pulse or selected interface
ANALOG OUTPUT:
- Connectors and Communication Ports
- Transmitter (Pulser)
- Receiver
- Analog OUT
- ETHERNET
- MULTI
- USB
- POWER
GENERAL:
- Dimensions 224×188×37 mm
- Display Color TFT 99×130 mm (1024×768 pixels) 65535 colors
- Weight 0.74 Kg without battery
- + 0.54 kg battery for 8 hours operation
- Operating Temperature -10 °C to 50 °C
- Storage Temperature -40 °C to 70 °C
- Power 100-240 VAC, 50 to 60 Hz, 50 VA max. for battery charging and operation
- Battery Built-in rechargeable LiIon battery pack, 3.6 V, 16 Ah
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|