| Specifications |
| Test Range |
0.500 in to 200 in (10 mm to 5000 mm)(in steel). In Hot Key Mode it has 13 preset values. In Fine Mode it is adjustable in step of 1mm. |
| Velocity |
0.0400 in/µs to 0.4000 in/µs (1000 m/sec to 9999 m/sec). In Hot Key Mode it has 7 preset values. In Fine Mode it is adjustable in step of 1 meter/second, |
| Delay |
Variable from 0 to 100 in (0 to 3000 mm) |
| Gain |
Total Amplifier Gain: 140 dB. Calibrated Gain: 100 dB adjustable in steps of 0.5,1,2,6,12 or 20 dB. |
| Rejection |
0 to 80% FSH with LED indication |
| Rectification |
Full wave rectification with filtering. |
| Frequency |
Broad Band amplifier 0.5 MHz to 15 MHz. |
| Test Modes |
Pulse Echo and Transmit/Receiver. |
| Connectors |
BNC and LEMO (Size 1) both are provided. |
| Monitor |
Dual gate adjustable in 1% of Screen width with Positive/Negative logic, Gate Expand modes. |
| Gate Expand |
Expands Range to width of the gate. |
| A-Scan Memory* |
200 Trace Patterns can be stored, recalled, printed or transferred to PC via RS-232 serial port. |
| Calibration Setup |
50 different calibration set-ups can be Stored and Recalled. |
| Software* |
Using “NewSoft TFT” software A-Scan with calibration set-ups can be transferred to PC via RS-232 serial link for storage in PC or printing. |
| Printer Attachment |
IBM compatible Printer having serial port can be directly attached to main unit for printing of stored A-Scan waveform with calibration data. |
| Display |
High brightness Color TFT LCD Display. Display area 320 x 240 pixel (122x92 mm). Eleven different color scheme options. |
| Full Screen |
By pressing Zoom key A-Scan can be displayed in Full Screen area. |
| Reference A-Scan* |
Reference A-Scan pattern of standard test object can be saved and recalled in the background for easy comparison during testing. |
| DAC* |
DAC curve can be entered using minimum 2 to maximum 10 points and then digitally drawn with –6dB and –14dB curves. |
| Digital Readout* and Trig. Function |
Thickness/Depth can be displayed in digital readout when using a normal probe and Beam path, Surface Distance and Depth are directly displayed when angle probe is in use. |
| Update Rate |
50Hz |
| Power |
Lithium-Ion Battery pack 14.4VDC, 4AH, gives 8 hours continuous operation from fully charged battery. |
| Charger |
Input Voltage 100 to 240 VAC. Charges status indicator is provided. |
| Temperature |
32° to 131°F (0 to 55° C) |
| Size |
5.98 in H x 10.04 in W x 2.76 in D (152x255x70 mm) |
| Weight |
5.07 lbs (2.3 kg.) with Battery. |